Health Report #109099

Establishment Name: Emu Starbucks
Report Date: 09/14/2012
Violation Type Violation Category Violation Items Violation Locations Violation Problems Violation Comments
Critical Backflow Prevention Device/Req Backflow prevention backflow/backsiphonage device vacuum breaker front counter area water line Not provided Found the water supply lines of the 2 espresso machines with unapproved backflow prevention devices (asse 1024 installed on water supply lines). To correct remove unapproved backflow prevention devices on espresso machine water supply lines and replace with back flow preventer with intermediate atmospheric vent meeting asse 1012 or 1022, example a watts 9d or watts sd-3. ,
Normal Wiping Cloths, Use Limitation Wiping cloth(s) wet front counter area espresso machine Stored on Drainboard Found wiping cloths stored in containers not submerged under sanitizer. To correct provide means to store wiping cloths completely submerged under sanitizer.
Normal Cleaning, Frequency/Restrictio Physical facilities/structures floors N/A Soiled Found the floor (under equipment, edges and corners) in the front counter area and storage room soiled with accumulation. To correct thoroughly clean floors and keep clean.