Health Report #108569

Establishment Name: Ann Arbor Marriott Courtyard
Report Date: 12/06/2010
Violation Type Violation Category Violation Items Violation Locations Violation Problems Violation Comments
Critical Backflow prevention Backflow/backsiphonage prevention device(s) Air gap 1 compartment sink food prep sink Not provided on Sink Observed kitcen food preparation sink located in the kitchen food preparation area without an air gap above the drain the sink drains into. To correct provide an air gap on the food prep sink drain line plumbing above the floor drain the sink drains into of atleast two pipe diameters of the drain line above the receiving floor drain. , observed kitcen food preparation sink located in the kitchen food preparation area without an air gap above the drain the sink drains into. To correct provide an air gap on the food prep sink drain line plumbing above the floor drain the sink drains into of atleast two pipe diameters of the drain line above the receiving floor drain. 12/15/2010 observed the kitchen food preparation sink located in the kitchen food preparation area provided with an air gap above the drain the sink drains into. This item was observed to be corrected by providing the proper air gap on the food preparation sink above the drain the sink drains into as required
Normal Light Bulbs, Protective Shield Light shielding Light shield(s) storage room light shields Not provided N/A