Health Report #104606

Establishment Name: Starbucks Coffee #2482
Report Date: 04/29/2013
Violation Type Violation Category Violation Items Violation Locations Violation Problems Violation Comments
Critical Backflow Prevention Device, Wh Backflow prevention backflow/backsiphonage device N/A Not provided The mop sink faucet has had the back flow preventer and wasting tee removed. Install an asse 1011 atmospheric vacuum breaker on the end of the chrome faucet. Connect to this atm. Vacuum breaker (down-stream) a wasting tee. The existing black rubber hose for the chemical dispenser will then be connected to the side port of the wasting tee.
Normal Equipment and Utensils, Air-Dr Clean equipment and utensil(s) N/A Stored/stacked wet A couple plastic food storage tubs were observed nested together in a front kitchen base cabinet. Ensure staff allow enough time for these items to air dry prior to stacking them in storage
Normal System Maintained in Good Repa Plumbing system water line(s) N/A Not maintained The two pvc drain lines for the ice machine / ice bin, and the drain line for the ice machine back flow preventer (1/2" copper) in the back kitchen have dropped down from their original position. Trim and/or support these drain lines to re-establish the required air gaps above the flood rim of the receiving floor sink (vertical air gap = 2x the discharge pipe diameter)
Normal Cleaning, Frequency and Restri Physical facilities/structures floors N/A Soiled The floor sink and under the front kitchen area base cabinets (especially where the floor meets the wall) are in need of a deep cleaning