Emu Starbucks

Contact Information

900 Oakwood Blvd.
Ypsilanti, MI 48197

Health Report - 09/03/2014 (1 critical incident(s))

(Critical) Found time/temperature control for safety (tcs) food, carafes of milk, cream, and nonfat milk in the self service counter which are on a time control policy without time control marks. Pic corrected by having employee empty carafes, wash carafes, refill carafes, and provide a 4 hour discard time control mark. Pic has been instructed to monitor and ensure employees are following time control policy, that is providing time control marks and discarding items when four hours have passed.

Health Report - 02/28/2014 (0 critical incident(s))

Found the floor under the front counter area soiled with accumulation of debris. To correct thoroughly clean floor and clean on a more frequent schedule.

Health Report - 08/28/2013 (0 critical incident(s))

Found the cooler and display case which does not hold time/temperature control for safety food, producing excessive noise. To correct verify that cooler is working properly and maintain in good repair.

Found the floor, under equipment, edges and corners soiled with accumulation of debris in the back kitchen area. Found the floor on the lower level storage room in front of the walk in freezer soiled with debris and water. To correct thoroughly clean floors and clean on a more frequent schedule.

Found wiping cloths stored above sanitizer in flat pans on the counter tops. To correct store wiping cloths under sanitizer after each use.

Health Report - 03/13/2013 (0 critical incident(s))

Found the floor, under equipment, edges and corners in the front counter and back kitchen area soiled with accumulation of debris. To correct thoroughly clean floors and keep clean.

Found unpeeled bananas stored uncovered in the walk in freezer. To correct cover bananas or stored in a covered storage container.

Health Report - 09/14/2012 (1 critical incident(s))

(Critical) Found the water supply lines of the 2 espresso machines with unapproved backflow prevention devices (asse 1024 installed on water supply lines). To correct remove unapproved backflow prevention devices on espresso machine water supply lines and replace with back flow preventer with intermediate atmospheric vent meeting asse 1012 or 1022, example a watts 9d or watts sd-3. ,

Found the floor (under equipment, edges and corners) in the front counter area and storage room soiled with accumulation. To correct thoroughly clean floors and keep clean.

Found wiping cloths stored in containers not submerged under sanitizer. To correct provide means to store wiping cloths completely submerged under sanitizer.

Health Report - 03/22/2012 (2 critical incident(s))

(Critical) Found cleaning chemicals stored on the bottom shelf with food utensils. Pic corrected by relocating cleaning chemicals to a location below and away from food utensils. , ,

(Critical) Found the drain line of the ice cream dipper well draining into a receptacle without air gap. To correct provide an air gap of at least 1 inch from the drain line and the rim of the receptacle. This is a repeated critical violation and a risk control plan form has been issued. , ,

Found no paper towels in the paper towel dispenser in the front counter area. To correct provide paper towels and keep dispenser stocked.

Found several shelves of the front counter storage cabinets soiled with splash and accumulation. To correct clean as soon as possible, and clean on a more frequent schedule.

Found the floor (under equipment, edges and corners) in the entire facility ( storage room, back prep area, and the front counter) soiled with accumulation. To correct thoroughly clean floors and clean on a more frequent schedule.

Health Report - 09/21/2011 (3 critical incident(s))

(Critical) Found the drain line of the ice cream dipper well without air gap. To correct provide an air gap of at least 1 inch from the drain line of the dipper well and the rim of the drain receptacle. ,

(Critical) Used a quat test kit and found the sanitizing solution flowing from the chemical dispenser in the sanitizing compartment of the 3 compartment sink at 100 ppm, below manufacturers specification of 200 ppm. To correct call for repair and manually mix sanitizing solutions and use test kit to verify proper concentration. ,

(Critical) Found time/temperature control for safety (tcs) food, a carton of heavy whipping cream 52°F in the right side of the under the counter 2 door cooler. Pic corrected by discarding heavy whipping cream and has been instructed not to use the right side of the under the counter 2 door cooler until repaired/replaced to hold tcs food at 41°F or lower. ,

Found wiping cloths for steam wands not submerged under sanitizer. To correct store wiping cloths submerged under sanitizer after each use.

Found 2 under the counter coolers in the front counter area without thermometers. To correct provide internal hanging thermometers for all coolers.

Found the dishwashing machine not in use and it's chemical feed tubes left in the floor drain receptacle. To correct either repair dishwashing machine or remove from facility and store chemical feed tubes in a more protected manner.

Found food supplies on bottom shelves not at least 6 inches off the floor and food utensils on the floor of the store room floor. To correct raise bottom shelves to be at least 6 inches off the floor, and store utensils on shelves.

Health Report - 03/31/2011 (0 critical incident(s))

Found the feed tubes of dishwashing machine chemicals (not in use ) being stored in the floor drain of the 3 compartment sink. To correct store feed tubes in a more protected manner. Found the bottom shelves of the storage room not at least 6 inches above the floor. To correct raise bottom shelves to be at least 6 inches above the floor.

Found the floor (under equipment, edges and corners) in the front counter area, back kitchen area and in the lower level storage room soiled with accumulation. To correct thoroughly clean floors and clean on a more frequent schedule.

Found ice scoop stored in the ice bin of the ice machine. To correct store ice scoop in a holder or clean container.

Found wiping cloths for espresso machine steam wands stored on espresso drainboard, and sanitizer container with low levels of sanitizer. To correct store wiping cloths in sanitizing container with adequate sanitizer which completely covers wiping cloth.

Found the floor of the walk in freezer in the lower level soiled with debris. To correct clean as soon as possible, and clean on a more frequent schedule.

Health Report - 10/04/2010 (2 critical incident(s))

(Critical) Observed three carafes of dairy product out at the customer self-service station. Two of the three did not have a use-by time sticker and the other one had a sticker from the prior day with a 4 pm discard time. These carafes were dumped out and sent to the dish washing sink. Three replacement clean carafes were filled and labeled with a four hour discard time--corrected

(Critical) Observed a fresh batch of the quat sanitizer to be at +/- 100 ppm. Corrected by adjusting the dispensing device to provide 200 ppm quat

Observed an employee with fake fingernails making drinks/cleaning and refilling dairy pitchers/transferring ice

Observed four decorative metal objects hanging from the ceiling above the beverage station that has excessive dust accumulation on them. After closing/before opening or on a holiday when foods and equipment is put away/protected these metal pieces need to be dusted/cleaned

Observed an employee drink in the basin of the back area hand washing sink, and a covered, partially eaten pastry on the rim of the same sink. Corrected by discarding these items

Observed a case of paper to-go pastry bags stored next to the hand washing sink and under the ice pail in the back room. These bags have water damage. Discard these bags and provide an alternative storage location for these items in the future

This incident (10403) does not have any more information on it

Four bulbs in the pastry display case. Provide shatter-proof light bulbs

Observed excessive dust accumulation on the condenser coils for the display cooler and the ice making machine. Thoroughly clean these coils for more efficient equipment operation